精品午夜国产在线观看不卡_日韩中文字幕在线综合网_日韩欧美在线观看一区二区视频t_亚洲天堂无码在线_免费看污的视频网站_亚洲美腿丝袜国产av_每日更新最新視頻_国产色欲婬乱视频网站免费_精品欧洲A∨无码一区二区三区_免费久久综合欧美

Dumbwaiter Elevator

Dumbwaiter Elevator

SANEI?SN debris elevator has the advantages of small volume, complete functions, smooth delivery, low price and other characteristics, widely used in transporting food restaurants and factory canteens, libraries and other debris transported, now on the market to use can be divided into two kinds, microcomputer control and PLC control, according to the work mode is divided into table and floor type, its speed from 0.4 meters to 1 meters, now mostly used to facilitate the installation of frame type, this structure has the advantages of convenient installation, use small space, and do not use special wells.

Introduction

SANEI Dumbwaiter Elevator, suitable for hotels, restaurants, banks, hospitals, canteens, libraries, kindergartens, factories, shopping malls, post office and other departments, for transporting food, tableware, daily necessities, books, medicine and other articles, many kinds of specifications. Elevator for the steel structure, comes with the computer room, the user does not need to design a well embedded stent, no special room, simple and convenient. Products in the design of the use of standardization, serialization, human nature, universal requirements, so that the production of debris elevator structure is strong, stable and reliable operation, is the best choice for you to use the elevator. Can also be based on the user's building structure, the production of non-standard debris elevator.
Simple operation, safe and reliable

Small space

No special wells, to the overall layout of the building and design convenience.

Low input cost

A one-time investment cost is low, can be repeatedly shifted to repeat the installation and use.

Simple operation

Easy to use, safe and reliable, easy maintenance.

Parameter Table

Rated load(kg) Persons Net dimension of car(mm) Dimension of door opening(mm) Dimension of hoistway(mm) Dimension of machine room(mm) Over head(mm) Pit depth(mm)
Width Depth Width Height Width Depth Width Depth Height
A B E F C D R T H Q P
1000 0.5/1.0 1300 1800 1200 2100 2400 2100 2750 3740 2500 4300 1400
2000 0.5/1.0 2000 2400 1600 2200 2950 2760 3000 4400 2500 4500 1500
3000 0.5 2500 2600 2000 2200 3550 2960 3700 3640 3000 4500 1500
4000 0.5 2100 3600 2000 2400 3450 3900 3450 3900 3000 4800 1500
5000 0.5 3000 3300 2400 2400 3950 3900 3950 3900 3000 4800 1500
8000 0.5 3300 3640 3950 2950 5370 4500 5370 4700 3000 6000 1560
10000 0.5 3500 3940 3950 2950 5670 4800 5670 5000 3000 6000 1560

Details PC version

Well layout

Standard Function

Function Description of functions
>Automatic operation The lift automatically runs and stops, opens / shuts the door according to designated command.
>Operation by operator The lift automatically runs and stops, manually shuts the door according to designated command.
>Overhaul operation Under repair and inspection conditions, the lift runs at inspection speed through operating
"slow up / slow down" buttons.
>Automatic door-shut
time-delay
After the car door has been opened completely, it keeps the door open condition. It automatically
shuts the dnnr after time-delav.
>Call for opening?of this floor When the lift is shutting the door or it does not start but has closed the door, when there is any
outer calling from this landing, it will reopen the door.
>Light curtain protection When optical curtain has been shaded,it immediately
stops door-shut action and automatically opens the door.
>Overload none?door-shut It does not shut the door in overload. And it is bright from overload lamp. The buzzer rings.
It shows CZ or overload In the car and does not start the Ilft
>Full-load direct running When it reaches the rated load, it only responds to internal selection instead of outer calling.
>Automatic lighting control In the stipulated time, If the lift does not receive any travel command, the lighting will a utomatically
die out. It automatically opens at command.
>Firefight return When It starts home landing fire-fighting switch, all the commands will be cancelled then.
The lift Immediately drives to the designated landing and park there.
>Mal-operation removal Repeatedly operate internal selective button to cancel mal-operation registration
>Main contactor protection After the lift executes door-shut command, if the door has not been closed within the
stipulated time, it will re-open the door and then shut it again.
>Service floor setting The lift only serves the set floor.
>Home landing floor setting Under the automatic condition, if there is?automatic ally run to the set landing.?no command within certain period, the car will
>Landing floor, direction display in the car It shows the landing floor of the lift, the direction where the lift is going to travel in the car,
>Direction chosen by driver The running direction Is determined by the driver's directive.
>Trouble diagnosis When there Is something wrong in the travel process, it will automatically diagnose the trouble
cause, display in the operation panel and automatically store the latest trouble Information.
>Safety circuit protection If safety circuit is disconnected, the lift will immediately stop the travel.
>Door Interlocking
protection
If It closes all of door Interlocking, it can then start the Ilft. If door Interlocking is disconn ected or
trembled, the lift will stop the operation.
>Travel contactor
protection
The system can detect whether motor circuit contactor action is reliable or not. If any abnorma
condition happens, it will stop the lift travel.

 

Function Description of functions
>Brake test protection It Implement real-time monitor to the brake open / shut through brake arm test switch. If the brake
has been opened improperly, the system will not allow the lift to start.
>Terminal speed change and?landing floor number correction After the system detect terminal switch in travel, the lift will be forced to change the speed and
automatically correct the landing floor display.
>Position-Limit protection If the system detects limit switch action, It will immediately stop the lift travel.
>Limit protectior If the system detects limit switch action, the whole system will Immediately lose power
>Over-speed protection When the lift up / down exceeds 1.2 times of the rated speed, it will cut off control mains and stop the lift travel.
>Landing floor, direction display The floor landing shows the landing floor that the lift travels and where it travels also.